Add to Cart
Steam Generator Rice Husk Steam Boiler 8 Ton Biomass Pellet Stove
Water tube boiler introduction
1. National Scientific and Technological Progress Second Prize
2. Singapore New Product Expo Golden Lion Award The furnace structure (D) is adopted with double drum, high technical content and energy saving and environmental protection. The series products won the second prize of national science and technology progress, won the golden lion of Singapore new product fair, are the national energy-saving engineering key promotion product.
Advantages of SZL type boiler design
1. By adopting the water-cooling system in packaged boilers which is usually used in power plant boilers, the boiler can achieve large heat transfer area, high heat transfer efficiency, low heat loss, good air tightness, and no distortion or dust leakage of the brickwork.
2. The front and back water-cooling wall tubes stretch themselves to the upper side of the chain grate, which increases the heating surface and overload capacity. The frames of the front and the rear arch are made of water-cooling tube wall, together with high-alumina cement, which can avoid the defects of the cracking and collapsing of the arch and extend its lifespan.
3. The distance between the front shaft and the rear shaft of the grate stoker is longer than other similar type domestic products. In this way, the combustion time of the fuel in the furnace is extended and the fuel combustion is more sufficient and the carbon content in the slag is decreased. Meanwhile, the actual heating surface of the grate is increased and the overload capacity is remarkably enhanced.
4. There are six independent wind chambers arranged lengthways and each chamber has an independent air adjuster, which can respectively adjust the air volume in each chamber so as to achieve the best combustion effect.
Techinal Parameter Table of SZL D type steam boiler
Model | Rated capacity | Rated pressure | Rated Feed water temperature | Rated steam temperature | Boiler heating area | Boiler efficiency | Weight | Delivery Mode |
t/h | Mpa | ℃ | ℃ | ㎡ | % | Ton | ||
SZH2-1.25/2.5-AII | 2 | 1.25/2.5 | 20 | 194/226 | 69.5 | 81 | 17/18.5 | Package Bolier |
SZH4-1.25/2.5-AII | 4 | 1.25/2.5 | 20 | 194/226 | 119.2 | 81 | 22/24.8 | |
SZL2-1.25/2.5-AII | 2 | 1.25/2.5 | 20 | 194/226 | 64.6 | 81.6 | 20/25 | |
SZL4-1.25/2.5-AII | 4 | 1.25/2.5 | 20 | 194/226 | 115.3 | 81.6 | 28/29 | |
SZL6-1.25/2.5-AII | 6 | 1.25/2.5 | 20 | 194/226 | 136.3 | 81.6 | 38/42 | |
SZL8-1.25/2.5-AII | 8 | 1.25/2.5 | 20 | 194/226 | 173 | 81.8 | 52 | |
SZL10-1.25/2.5-AII | 10 | 1.25/2.5 | 20 | 194/226 | 233 | 82 | 68 | Assembled Boiler |
SZL15-1.25/2.5-AII | 15 | 1.25/2.5 | 20 | 194/226 | 307.3 | 82.3 | 30 | |
SZL20-1.25/2.5-AII | 20 | 1.25/2.5 | 20 | 194/226 | 725.2 | 82.3 | 40 |
This is just part of the product parameters, if you want to know more detailed parameters of the boiler, please feel free to contact us.
Factory showing